Seguin Engine Facility / Caterpillar Inc. / Seguin, Texas
Project Overview:
ACS designed and constructed new diesel engine production test cells, for up to 1,200 hp. The test cell improves production thru-put by shortening engine test cycle time. The total engine test time is 12 minutes, floor to floor (in and out of test cell).
Key Performance Features:
- Fully Automated Test Cells – Operator not required to enter the test cell under normal operation.
- All test cells are identical, allowing all engines to be tested in all cells.
- Automated in-floor TracVeyor System - Deliver test pallets/engines to and from the test cells and engine rig area.
- Assembly line style rig and de-rig area. Design team coordination to reduce project schedule time, and completed under budget.
ACS Services: Integrated Project Delivery
Project Duration: 12 months