Emissions R&D And Control System
Detroit Diesel - Rocky Mount, NC
Project Features: Process Automation, PLC System, Continuous Process, Advanced Process Controls

ACS designed, constructed and commissioned a new CVS dilution tunnel for emissions testing and a new PLC system that controls the combustion and dilution of air functions necessary for CVS emissions testing. The installation of a new chilled water and hot water system is used to support the air handling units.
Key Performance Features:
- Provided the complete design, procurement, construction and commissioning activities
- Designed, fabricated and commissioned the CVS dilution tunnel and controls
- Integrated the PLC system with CDC’s proprietary data acquisition and control system
ACS Services:
Design – Build